Search found 5 matches

by anotherPull
Sun Jun 20, 2021 11:43 pm
Forum: Maintenance and Repair
Topic: Odd part on S1 VII board, and autofill problem
Replies: 6
Views: 2368

Re: Odd part on S1 VII board, and autofill problem

Yes, at 20A GFCI, did not trip. I measured 400 - 600 kOhms, so not very much leakage. I cleaned up the heater I pulled out and dried it, it's now > 50 meg-ohm, so probably fine.
by anotherPull
Thu Jun 17, 2021 9:33 am
Forum: Maintenance and Repair
Topic: Odd part on S1 VII board, and autofill problem
Replies: 6
Views: 2368

Re: Odd part on S1 VII board, and autofill problem

Problem solved. There was some stray leakage current from the boiler heating element affecting the probe ground. Replaced heater, back to normal.
by anotherPull
Sat Jun 05, 2021 1:25 pm
Forum: VII Out-of-Warranty Problems
Topic: Vivaldi-II Group Heating Element
Replies: 1
Views: 16202

Re: Vivaldi-II Group Heating Element

Confirmed, my 2007 group element pin is threaded. Seems to be M2 thread. It was impossible to see that it was threaded, so your post was very helpful, thanks!

The replacement element was not threaded, the threaded end of the pin slipped into the hole.
by anotherPull
Thu Jun 03, 2021 2:28 pm
Forum: Maintenance and Repair
Topic: Odd part on S1 VII board, and autofill problem
Replies: 6
Views: 2368

Re: Odd part on S1 VII board, and autofill problem

I took it off. It was only held on by flux and did not appear to have been soldered down previously. It must have been there since the firmware upgrade in 2008. I cleaned the area with IPA to get the flux off. It did not correct the issue. I'm in contact with Chris's Coffee, hoping not to need a new...
by anotherPull
Wed Jun 02, 2021 9:56 pm
Forum: Maintenance and Repair
Topic: Odd part on S1 VII board, and autofill problem
Replies: 6
Views: 2368

Odd part on S1 VII board, and autofill problem

I've been tracking down an autofill problem on an S1 VII I've owned since 2007. I noticed this resistor on the board that looks like it should not be there. Anyone seen anything like this? I have narrowed the issue down to when the fill probe ground is connected, the fill does not work. Solenoid, va...