Search found 4 matches

by DinoCoffeno
Thu Feb 11, 2021 12:57 pm
Forum: Maintenance and Repair
Topic: S1 Vivaldi II boiler pump won't shut off (sometimes)
Replies: 6
Views: 3743

Re: S1 Vivaldi II boiler pump won't shut off (sometimes)

My problem is that the pump will not stop and it causes an overflow out the relief valve so tube is not plugged.
I think my S1 has formed its own energy and healed thy self :lol:
It’s working well for now. One thing I did was that I squeezed the ground wire tighter on the connector on the tank
by DinoCoffeno
Tue Jan 19, 2021 9:54 am
Forum: Maintenance and Repair
Topic: Fuse stuck in machine
Replies: 10
Views: 13871

Re: Fuse stuck in machine

I had the same problem. It appears that on the spring end of the fuse holder slightly melted and caused the fuse to stick inside and not make contact so I just replaced the fuse holder
by DinoCoffeno
Fri Jan 15, 2021 2:11 am
Forum: Maintenance and Repair
Topic: S1 Vivaldi II boiler pump won't shut off (sometimes)
Replies: 6
Views: 3743

Re: S1 Vivaldi II boiler pump won't shut off (sometimes)

Thanks Chas Yes this has been an intermittent problem, but it’s been happening more frequent lately. I will keep trying to get it to happen again and short out the water level sensor. One thing I have noticed that when the water level drops below the sensor there is a 4 second delay before the pump ...
by DinoCoffeno
Wed Jan 13, 2021 7:48 pm
Forum: Maintenance and Repair
Topic: S1 Vivaldi II boiler pump won't shut off (sometimes)
Replies: 6
Views: 3743

S1 Vivaldi II boiler pump won't shut off (sometimes)

Hello All, I have a Vivaldi II S1 and “sometimes“ the pump to the boiler will not shut off. Usually when the machine is first turned on and is warming up. The pump will start up and pump until it pops the relief valve on top. I am a DIY person and have scoured the Internet looking for answers. There...